Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Poster

Perceiving and controlling simulated ego-rotations by optic flow: Influence of field of view (FOV) and display devices on ego-motion perception

MPG-Autoren
/persons/resource/persons84199

Schulte-Pelkum,  J
Department Human Perception, Cognition and Action, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84170

Riecke,  BE
Department Human Perception, Cognition and Action, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84287

von der Heyde,  M
Department Human Perception, Cognition and Action, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons83839

Bülthoff,  HH
Department Human Perception, Cognition and Action, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

Externe Ressourcen
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Schulte-Pelkum, J., Riecke, B., von der Heyde, M., & Bülthoff, H. (2002). Perceiving and controlling simulated ego-rotations by optic flow: Influence of field of view (FOV) and display devices on ego-motion perception. Poster presented at 10th Annual Workshop on Object Perception and Memory (OPAM 2002), Kansas City, KS, USA.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-0013-DEAD-5
Zusammenfassung
This study investigated humans ability to control simulated ego-rotations from optic flow. The stimuli consisted of limited lifetime dots on a dark background. In a within-subject design, performance was tested using a curved projection screen (FOV 86°×63°), a HMD (40°×30°), and blinders (40°×30°) that restricted the FOV on the screen. Participants typically undershot intended turn angles. Performance was best with the screen (gain factor 0.77) and worst with the HMD (gain 0.57). A significant difference between blinders (gain 0.73) and HMD indicates that different display devices can influence ego-motion perception differentially, even if the physical FOVs are equal.