English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Minimizing electrostatic charging of an aperture used to produce in-focus phase contrast in the TEM

MPS-Authors
/persons/resource/persons123013

Danev,  Radostin
Baumeister, Wolfgang / Molecular Structural Biology, Max Planck Institute of Biochemistry, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Glaeser, R. M., Sassolini, S., Cambie, R., Jin, J., Cabrini, S., Schmid, A. K., et al. (2013). Minimizing electrostatic charging of an aperture used to produce in-focus phase contrast in the TEM. ULTRAMICROSCOPY, 135, 6-15. doi:10.1016/j.ultramic.2013.05.023.


Cite as: https://hdl.handle.net/11858/00-001M-0000-0014-D124-A
Abstract
Microfabricated devices designed to provide phase contrast in the transmission electron microscope must be free of phase distortions caused by unexpected electrostatic effects. We find that such phase distortions occur even when a device is heated to 300 degrees C during use in order to avoid the formation of polymerized, carbonaceous contamination. Remaining factors that could cause unwanted phase distortions include patchy variations in the work function of a clean metal surface, radiation-induced formation of a localized oxide layer, and creation of a contact potential between an irradiated area and the surround due to radiation-induced structural changes. We show that coating a microfabricated device with evaporated carbon apparently eliminates the problem of patchy variation in the work function. Furthermore, we show that a carbon-coated titanium device is superior to a carbon-coated gold device, with respect to radiation-induced electrostatic effects. A carbon-coated, hybrid double-sideband/single-sideband aperture is used to record in-focus, cryo-EM images of monolayer crystals of streptavidin. Images showing no systematic phase error due to charging are achievable under conditions of lowdose data collection. The contrast in such in-focus images is sufficient that one can readily see individual streptavidin tetramer molecules. Nevertheless, these carbon-coated devices perform well for only a limited length of time, and the cause of failure is not yet understood. (C) 2013 Elsevier B.V. All rights reserved.