Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

Comparison of SILAC and mTRAQ Quantification for Phosphoproteomics on a Quadrupole Orbitrap Mass Spectrometer

MPG-Autoren
/persons/resource/persons77870

Cox,  Jürgen
Mann, Matthias / Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, Max Planck Society;

/persons/resource/persons78611

Schaab,  Christoph
Mann, Matthias / Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, Max Planck Society;

Externe Ressourcen
Es sind keine externen Ressourcen hinterlegt
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Oppermann, F. S., Klammer, M., Bobe, C., Cox, J., Schaab, C., Tebbe, A., et al. (2013). Comparison of SILAC and mTRAQ Quantification for Phosphoproteomics on a Quadrupole Orbitrap Mass Spectrometer. JOURNAL OF PROTEOME RESEARCH, 12(9), 4089-4100. doi:10.1021/pr400417g.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-0015-7AFB-F
Zusammenfassung
Advances in mass spectrometric methodology and instrumentation have promoted a continuous increase in analytical performance in the field of phosphoproteomics. Here, we employed the recently introduced quadrupole Orbitrap (Q Exactive) mass spectrometer for quantitative signaling analysis to a depth of more than 15 000 phosphorylation sites. In parallel to the commonly used SILAC approach, we evaluated the nonisobaric chemical labeling reagent mTRAQ as an alternative quantification technique. Both enabled high phosphoproteome coverage in H3122 lung cancer cells. Replicate quantifications by mTRAQ identified almost as many significant phosphorylation changes upon treatment with ALK kinase inhibitor crizotinib as found by SILAC quantification. Overall, mTRAQ was slightly less precise than SILAC as evident from a somewhat higher variance of replicate phosphosite ratios. Direct comparison of SILAC- and mTRAQ-quantified phosphosites revealed that the majority of changes were detected by either quantification techniques, but also highlighted the aspect of false negative identifications in quantitative proteomics applications. Further inspection of crizotinib-regulated phosphorylation changes unveiled interference with multiple antioncogenic mechanisms downstream of ALK fusion kinase in H3122 cells. In conclusion, our results demonstrate a strong analytical performance of the Q Exactive in global phosphoproteomics, and establish mTRAQ quantification as a useful alternative to metabolic isotope labeling.