Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

Deformation mechanisms in micron-sized PST TiAl compression samples: Experiment and model

MPG-Autoren
Es sind keine MPG-Autoren in der Publikation vorhanden
Externe Ressourcen
Es sind keine externen Ressourcen hinterlegt
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Rester, M., Fischer, F. D., Kirchlechner, C., Schmoelzer, T., Clemens, H. J., & Dehm, G. (2011). Deformation mechanisms in micron-sized PST TiAl compression samples: Experiment and model. Acta Materialia, 59(9), 3410-3421. doi:10.1016/j.actamat.2011.02.016.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-001A-20E4-A
Zusammenfassung
Titanium aluminides are the most promising intermetallics for use in aerospace and automotive applications. Consequently, it is of fundamental interest to explore the deformation mechanisms occurring in this class of materials. One model material which is extensively used for such studies are polysynthetically twinned (PST) TiAl crystals, which consist predominantly of parallel γ-TiAl and, fewer, α2-Ti3Al lamellae. In the present study, PST TiAl crystals with a nominal composition of Ti–50 at.% Al were machined by means of the focused ion beam (FIB) technique into miniaturized compression samples with a square cross-section of approximately 9 µm x 9 µm. Compression tests on the miniaturized samples were performed in situ inside a scanning electron microscope using a microindenter equipped with a diamond flat punch. After deformation, thin foils were cut from the micro-compression samples and thinned to electron transparency using a FIB machine in order to study the deformation structure by transmission electron microscopy (TEM). The TEM studies reveal mechanical twinning as the main deformation mechanism at strains of 5.4%, while at strains of 8.3% dislocation glide becomes increasingly important. The experimentally observed twins scale in size with the width of the γ-TiAl lamella. A kinematic and thermodynamic model is developed to describe the twin-related length change of the micro-compression sample at small strains as well as the relationship of an increase of twin width with increasing γ-TiAl lamella thickness. The developed twin model predicts a width of the twins in the range of a few nanometers, which is in agreement with experimental findings.