English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Calibration of TCCON column-averaged CO2: the first aircraft campaign over European TCCON sites

MPS-Authors
/persons/resource/persons62379

Geibel,  Marc
Department Biogeochemical Systems, Prof. M. Heimann, Max Planck Institute for Biogeochemistry, Max Planck Society;

/persons/resource/persons62373

Feist,  Dietrich G.
Atmospheric Remote Sensing Group, Dr. D. Feist, Department Biogeochemical Systems, Prof. M. Heimann, Max Planck Institute for Biogeochemistry, Max Planck Society;

/persons/resource/persons62381

Gerbig,  Christoph
Airborne Trace Gas Measurements and Mesoscale Modelling, Dr. habil. C. Gerbig, Department Biogeochemical Systems, Prof. M. Heimann, Max Planck Institute for Biogeochemistry, Max Planck Society;

/persons/resource/persons62444

Kolle,  Olaf
Service Facility Field Measurements & Instrumentation, O. Kolle, Max Planck Institute for Biogeochemistry, Max Planck Society;

/persons/resource/persons62457

Lavrič,  J. V.
Tall Tower Atmospheric Gas Measurements, Dr. J. Lavrič, Department Biogeochemical Systems, Prof. M. Heimann, Max Planck Institute for Biogeochemistry, Max Planck Society;

External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)

BGC2179.pdf
(Publisher version), 2MB

BGC2179D.pdf
(Publisher version), 3MB

Supplementary Material (public)
There is no public supplementary material available
Citation

Messerschmidt, J., Geibel, M., Blumenstock, T., Chen, H., Deutscher, N. M., Engel, A., et al. (2011). Calibration of TCCON column-averaged CO2: the first aircraft campaign over European TCCON sites. Atmospheric Chemistry and Physics, 11, 10765-10777. doi:10.5194/acp-11-10765-2011.


Cite as: https://hdl.handle.net/11858/00-001M-0000-0024-6114-2
Abstract
The Total Carbon Column Observing Network (TCCON) is a ground-based network of Fourier Transform Spectrometer (FTS) sites around the globe, where the column abundances of CO2, CH4, N2O, CO and O2 are measured. CO2 is constrained with a precision better than 0.25% (1-σ). To achieve a similarly high accuracy, calibration to World Meteorological Organization (WMO) standards is required. This paper introduces the first aircraft calibration campaign of five European TCCON sites and a mobile FTS instrument. A series of WMO standards in-situ profiles were obtained over European TCCON sites via aircraft and compared with retrievals of CO2 column amounts from the TCCON instruments. The results of the campaign show that the FTS measurements are consistently biased 1.1% ± 0.2% low with respect to WMO standards, in agreement with previous TCCON calibration campaigns. The standard a priori profile for the TCCON FTS retrievals is shown to not add a bias. The same calibration factor is generated using aircraft profiles as a priori and with the TCCON standard a priori. With a calibration to WMO standards, the highly precise TCCON CO2 measurements of total column concentrations provide a suitable database for the calibration and validation of nadir-viewing satellites.