Aortic pulse wave velocities using real-time phase-contrast MRI.

MPG-Autoren
/persons/resource/persons59192

Joseph,  A. A.
Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons15516

Merboldt,  K. D.
Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons15082

Frahm,  J.
Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society;

Externe Ressourcen
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)

2155746.pdf
(Verlagsversion), 4MB

Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Joseph, A. A., Fasshauer, M., Merboldt, K. D., & Frahm, J. (2015). Aortic pulse wave velocities using real-time phase-contrast MRI. The Open Medical Imaging Journal, 9, 9-14. doi:10.2174/1874347101509010009.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-0026-CE41-E
Zusammenfassung
Purpose: To evaluate aortic pulse wave velocities obtained by real-time phase-contrast (PC) MRI in comparison to cine PC MRI. Methods: Real-time PC MRI of eight healthy volunteers employed highly undersampled radial FLASH sequences and phase-sensitive image reconstructions by regularized nonlinear inversion (NLINV) at 40 ms temporal resolution and 1.3 mm in-plane resolution. Pulse wave velocities were analyzed for combinations of 2, 3 and 4 locations of aortic flow using time-to-upslope and cross-correlation methods. Results: For the time-to-upslope analysis mean pulse wave velocities ranged from 3.5 to 3.9 m s-1 for real-time PC MRI and from 3.5 to 3.8 m s-1 for cine PC MRI. A cross-correlation analysis of the same data resulted in 2.9 to 3.3 m s-1 and 3.3 to 3.7 m s-1, respectively. Conclusion: Real-time PC MRI determined aortic pulse wave velocities from single cardiac cycles in close correspondence to values obtained by cine PC MRI.