English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONS
  This item is discarded!DetailsSummary

Discarded

Journal Article

The OASIS(R) HLB muElution plate as a one-step platform for manual high-throughput in-gel digestion of proteins and peptide desalting

MPS-Authors

Franz,  T.
Max Planck Society;

Li,  X.
Max Planck Society;

External Resource

(No access)

Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Franz, T., & Li, X. (2012). The OASIS(R) HLB muElution plate as a one-step platform for manual high-throughput in-gel digestion of proteins and peptide desalting. Proteomics, 12(15-16), 2487-92. doi:10.1002/pmic.201100354.


Abstract
Separation or prefractionation of proteins by gel electrophoresis, followed by in-gel proteolytic digest and analysis by MS is a typical standard application in proteomics. For many laboratories, it is not cost-effective to use a robot with all its drawbacks. On the other hand, manual digest is time consuming and not free of error if many samples are processed at the same time. The OASIS(R) HLB muElution plate allows the handling of 96 samples for protein in-gel digest and peptide desalting in a semiautomatic way. Using multichannel pipettes, solutions are added quickly, and with the use of the positive pressure-96 stand all solutions are removed simultaneously. In this article, a complete and detailed protocol for the use of the OASIS(R) HLB muElution plate is introduced and its effectiveness is shown with 2D- and 1D-gel samples.