Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

In-focus electron microscopy of frozen-hydrated biological samples with a Boersch phase plate

MPG-Autoren
/persons/resource/persons182749

Lacher,  M.
Micro Systems Technology, Center of Advanced European Studies and Research (caesar), Max Planck Society;

/persons/resource/persons182763

Schmitz,  S.
Micro Systems Technology, Center of Advanced European Studies and Research (caesar), Max Planck Society;

/persons/resource/persons182738

Holik,  P.
Micro Systems Technology, Center of Advanced European Studies and Research (caesar), Max Planck Society;

Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Barton, B., Rhinow, D., Walter, A., Schröder, R., Benner, G., Majorovits, E., et al. (2011). In-focus electron microscopy of frozen-hydrated biological samples with a Boersch phase plate. Ultramicroscopy, 111(12), 1696-1705. doi:S0304-3991(11)00225-7 [pii];10.1016/j.ultramic.2011.09.007 [doi].


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-0028-62F8-1
Zusammenfassung
We report the implementation of an electrostatic Einzel lens (Boersch) phase plate in a prototype transmission electron microscope dedicated to aberration-corrected cryo-EM. The combination of phase plate, C(s) corrector and Diffraction Magnification Unit (DMU) as a new electron-optical element ensures minimal information loss due to obstruction by the phase plate and enables in-focus phase contrast imaging of large macromolecular assemblies. As no defocussing is necessary and the spherical aberration is corrected, maximal, non-oscillating phase contrast transfer can be achieved up to the information limit of the instrument. A microchip produced by a scalable micro-fabrication process has 10 phase plates, which are positioned in a conjugate, magnified diffraction plane generated by the DMU. Phase plates remained fully functional for weeks or months. The large distance between phase plate and the cryo sample permits the use of an effective anti-contaminator, resulting in ice contamination rates of <0.6nm/h at the specimen. Maximal in-focus phase contrast was obtained by applying voltages between 80 and 700mV to the phase plate electrode. The phase plate allows for in-focus imaging of biological objects with a signal-to-noise of 5-10 at a resolution of 2-3nm, as demonstrated for frozen-hydrated virus particles and purple membrane at liquid-nitrogen temperature