Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

Efficient generation of T2*-weighted contrast by interslice echo-shifting for human functional and anatomical imaging at 9.4 Tesla

MPG-Autoren
/persons/resource/persons83898

Ehses,  P
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons192600

Bause,  J
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84213

Shajan,  G
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84187

Scheffler,  K
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

Externe Ressourcen
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Ehses, P., Bause, J., Shajan, G., & Scheffler, K. (2015). Efficient generation of T2*-weighted contrast by interslice echo-shifting for human functional and anatomical imaging at 9.4 Tesla. Magnetic Resonance in Medicine, 74(6), 1698-1704. doi:10.1002/mrm.25570.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-002A-4381-1
Zusammenfassung
Purpose Standard gradient-echo sequences are often prohibitively slow for inline image-weighted imaging as long echo times prolong the repetition time of the sequence. Echo-shifting offers a way out of this dilemma by allowing an echo time that exceeds the repetition time. The purpose of this work is to present a gradient-echo sequence that is optimized for multislice inline image-weighted imaging applications by combining echo-shifting with an interleaved slice excitation order. Theory and Methods This combined approach offers two major advantages: First, it combines the advantages of both concepts, that is, echo time and pulse repetition time can be significantly increased without affecting scan time. Second, there is no echo-shifting related signal loss associated with this concept as only a single radiofrequency pulse is applied per pulse repetition time and slice. Results A 9.4 Tesla high-resolution inline image-weighted anatomical brain scan of the proposed sequence is compared to a standard gradient-echo. Furthermore, results from 9.4 Tesla blood oxygen level dependent functional magnetic resonance imaging experiments with an in-plane resolution of 0.8 × 0.8 mm2 are presented. Conclusion The proposed sequence allows for efficient generation of inline image-weighted contrast by combining echo-shifting with an interleaved slice excitation order.