Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Meeting Abstract

A parallel transmit spectral-spatial pulse design method for ultra-high field MRS combining LSQR and optimal control based optimization

MPG-Autoren
/persons/resource/persons192743

Shao,  T
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons133464

Avdievich,  NI
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84402

Henning,  A
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Shao, T., Zhang, Y., Avdievich, N., Glaser, S., & Henning, A. (2015). A parallel transmit spectral-spatial pulse design method for ultra-high field MRS combining LSQR and optimal control based optimization. Magnetic Resonance Materials in Physics, Biology and Medicine, 28(Supplement 1), S404-S405.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-002A-443F-2
Zusammenfassung
Purpose/Introduction: Ultra high field MRI benefits 1H MRS applications by offering increased chemical shift dispersion, improved SNR and reduced J-coupling, but also raises technical challenges such as shortened T2 and T2* relaxation times, severe chemical shift displacement artifacts and signal disuniformity. In this work, a parallel transmission based pulse design method that combines LSQR [1] and optimal control (OC) [2] approaches is proposed to achieve spectral-spatial pulses (SPSP) that tackle aforementioned technical challenges in ultra-high field 1H MRS. Subjects and Methods: The B1 + B0 field maps [3] were acquired with a home-built 8-channel TxRx array head coil [4] and a spherical spectroscopy phantom on a 9.4 T Magnetom SIEMENS scanner (SIEMENS Healthcare, Erlangen, Germany), as shown in Fig 1a. The desired excitation pattern is a uniform rectangle (5 cm 9 7.5 cm) in a slice of 22 cm FOV, as shown in Fig 1b, and a uniform band along the spectral axis, with 2 kHz (or 4 ppm) bandwidth that is sufficient to cover the spectral range of interest at 9.4 Tesla (1.6 kHz). Based on a spiral trajectory, a spatially selective excitation pulse is designed first using the LSQR method [1], and is afterwards used as an initial guess for the OC method [2] for further optimization into an SPSP pulse. Spinor-domain based Bloch simulations were implemented to produce the saturation profiles of the designed pulses. Results: By comparison of the spectral-spatial saturation profiles of the pulses (duration 4.10 ms, maximum B1 + amplitude 34.5 uT) designed using the OC method (Fig. 2) and the combined method (Fig. 3), it can be seen that the initial guess calculated by the LSQR method helps to direct the OC method to an optimized global minimum instead of sticking in the local minimum with bad performance. Discussion/Conclusion: The simulation results show promising performance of the proposed method in parallel transmit SPSP pulse design. Similar excitation and saturation pulses may be used in future for FID MRSI at 9.4 T [5, 6], which could lead to a homogeneous spatial-spectral excitation profile and better lipid suppression at reduced SAR deposition in comparison to spatially selective outer volume suppression.