High-resolution quantitative sodium imaging at 9.4 tesla

MPS-Authors
/persons/resource/persons84405

Mirkes,  CC
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons83973

Hoffmann,  J
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84213

Shajan,  G
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84145

Pohmann,  R
Dept. Empirical Inference, Max Planck Institute for Intelligent Systems, Max Planck Society;
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84187

Scheffler,  K
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Mirkes, C., Hoffmann, J., Shajan, G., Pohmann, R., & Scheffler, K. (2015). High-resolution quantitative sodium imaging at 9.4 tesla. Magnetic Resonance in Medicine, 73(1), 342-351. doi:10.1002/mrm.25096.


Cite as: https://hdl.handle.net/11858/00-001M-0000-002A-4795-4
Abstract
Purpose Investigation of the feasibility to perform high-resolution quantitative sodium imaging at 9.4 Tesla (T). Methods A proton patch antenna was combined with a sodium birdcage coil to provide a proton signal without compromising the efficiency of the X-nucleus coil. Sodium density weighted images with a nominal resolution of 1 × 1 × 5 mm3 were acquired within 30 min with an ultrashort echo time sequence. The methods used for signal calibration as well as for B0, B1, and off-resonance correction were verified on a phantom and five healthy volunteers. Results An actual voxel volume of roughly 40 μL could be achieved at 9.4T, while maintaining an acceptable signal-to-noise ratio (8 for brain tissue and 35 for cerebrospinal fluid). The measured mean sodium concentrations for gray and white matter were 36 ± 2 and 31 ± 1 mmol/L of wet tissue, which are comparable to values previously reported in the literature. Conclusion The reduction of partial volume effects is essential for accurate measurement of the sodium concentration in the human brain. Ultrahigh field imaging is a viable tool to achieve this goal due to its increased sensitivity.