日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細


公開

学術論文

Incoherent x-ray scattering in single molecule imaging

MPS-Authors
/persons/resource/persons195316

Slowik,  Jan Malte
International Max Planck Research School for Ultrafast Imaging & Structural Dynamics (IMPRS-UFAST), Max Planck Institute for the Structure and Dynamics of Matter, Max Planck Society;
Center for Free-Electron Laser Science, DESY, Hamburg, Germany;
Department of Physics, University of Hamburg, Hamburg, Germany;
The Hamburg Centre for Ultrafast Imaging, Hamburg, Germany;

External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
フルテキスト (公開)

NJP_16_7_073042.pdf
(出版社版), 704KB

付随資料 (公開)
There is no public supplementary material available
引用

Slowik, J. M., Son, S.-K., Dixit, G., Jurek, Z., & Santra, R. (2014). Incoherent x-ray scattering in single molecule imaging. New Journal of Physics, 16(7):. doi:10.1088/1367-2630/16/7/073042.


引用: https://hdl.handle.net/11858/00-001M-0000-002B-228E-F
要旨
Imaging of the structure of single proteins or other biomolecules with atomic resolution would be enormously beneficial to structural biology. X-ray free-electron lasers generate highly intense and ultrashort x-ray pulses, providing a route towards imaging of single molecules with atomic resolution. The information on molecular structure is encoded in the coherent x-ray scattering signal. In contrast to crystallography there are no Bragg reflections in single molecule imaging, which means the coherent scattering is not enhanced. Consequently, a background signal from incoherent scattering deteriorates the quality of the coherent scattering signal. This background signal cannot be easily eliminated because the spectrum of incoherently scattered photons cannot be resolved by usual scattering detectors. We present an ab initio study of incoherent x-ray scattering from individual carbon atoms, including the electronic radiation damage caused by a highly intense x-ray pulse. We find that the coherent scattering pattern suffers from a significant incoherent background signal at high resolution. For high x-ray fluence the background signal becomes even dominating. Finally, based on the atomic scattering patterns, we present an estimation for the average photon count in single molecule imaging at high resolution. By varying the photon energy from 3.5 keV to 15 keV, we find that imaging at higher photon energies may improve the coherent scattering signal quality.