High-power 1H composite pulse decoupling provides artifact free exchange-mediated saturation transfer (EST) experiments.

MPS-Authors
/persons/resource/persons198433

Chakrabarti,  K. S.
Department of NMR Based Structural Biology, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons135836

Pratihar,  S.
Department of NMR Based Structural Biology, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons14824

Becker,  S.
Department of NMR Based Structural Biology, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons15147

Griesinger,  C.
Department of NMR Based Structural Biology, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons15424

Lee,  D.
Department of NMR Based Structural Biology, MPI for biophysical chemistry, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)

2338347_Suppl.pdf
(Supplementary material), 4MB

Citation

Chakrabarti, K. S., Ban, D., Pratihar, S., Reddy, J. G., Becker, S., Griesinger, C., et al. (2016). High-power 1H composite pulse decoupling provides artifact free exchange-mediated saturation transfer (EST) experiments. Journal of Magnetic Resonance, 269, 65-69. doi:10.1016/j.jmr.2016.05.013.


Cite as: https://hdl.handle.net/11858/00-001M-0000-002B-3552-1
Abstract
Exchange-mediated saturation transfer (EST) provides critical information regarding dynamics of molecules. In typical applications EST is studied by either scanning a wide range of (15)N chemical shift offsets where the applied (15)N irradiation field strength is on the order of hundreds of Hertz or, scanning a narrow range of (15)N chemical shift offsets where the applied (15)N irradiation field-strength is on the order of tens of Hertz during the EST period. The (1)H decoupling during the EST delay is critical as incomplete decoupling causes broadening of the EST profile, which could possibly result in inaccuracies of the extracted kinetic parameters and transverse relaxation rates. Currently two different (1)H decoupling schemes have been employed, intermittently applied 180° pulses and composite-pulse-decoupling (CPD), for situations where a wide range, or narrow range of (15)N chemical shift offsets are scanned, respectively. We show that high-power CPD provides artifact free EST experiments, which can be universally implemented regardless of the offset range or irradiation field-strengths.