English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Model-based reconstruction for real-time phase-contrast flow MRI: Improved spatiotemporal accuracy.

MPS-Authors
/persons/resource/persons195503

Tan,  Z.
Biomedical NMR Research GmbH, MPI for Biophysical Chemistry, Max Planck Society;

/persons/resource/persons136471

Roeloffs,  V. B.
Biomedical NMR Research GmbH, MPI for Biophysical Chemistry, Max Planck Society;

/persons/resource/persons15968

Voit,  D.
Biomedical NMR Research GmbH, MPI for Biophysical Chemistry, Max Planck Society;

/persons/resource/persons59192

Joseph,  A. A.
Biomedical NMR Research GmbH, MPI for Biophysical Chemistry, Max Planck Society;

/persons/resource/persons85321

Untenberger,  M.
Biomedical NMR Research GmbH, MPI for Biophysical Chemistry, Max Planck Society;

/persons/resource/persons15516

Merboldt,  K. D.
Biomedical NMR Research GmbH, MPI for Biophysical Chemistry, Max Planck Society;

/persons/resource/persons15082

Frahm,  J.
Biomedical NMR Research GmbH, MPI for Biophysical Chemistry, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)

2351084_Suppl_1.avi
(Supplementary material), 761KB

2351084_Suppl_2.avi
(Supplementary material), 490KB

2351084_Suppl_3.avi
(Supplementary material), 893KB

2351084_Suppl_4.avi
(Supplementary material), 443KB

2351084_Suppl_5.avi
(Supplementary material), 2MB

2351084_Suppl_6.avi
(Supplementary material), 525KB

Citation

Tan, Z., Roeloffs, V. B., Voit, D., Joseph, A. A., Untenberger, M., Merboldt, K. D., et al. (2017). Model-based reconstruction for real-time phase-contrast flow MRI: Improved spatiotemporal accuracy. Magnetic Resonance in Medicine, 77(3), 1082-1093. doi:10.1002/mrm.26192.


Cite as: https://hdl.handle.net/11858/00-001M-0000-002B-8446-A
Abstract
PURPOSE: To develop a model-based reconstruction technique for real-time phase-contrast flow MRI with improved spatiotemporal accuracy in comparison to methods using phase differences of two separately reconstructed images with differential flow encodings. METHODS: The proposed method jointly computes a common image, a phase-contrast map, and a set of coil sensitivities from every pair of flow-compensated and flow-encoded datasets obtained by highly undersampled radial FLASH. Real-time acquisitions with five and seven radial spokes per image resulted in 25.6 and 35.7 ms measuring time per phase-contrast map, respectively. The signal model for phase-contrast flow MRI requires the solution of a nonlinear inverse problem, which is accomplished by an iteratively regularized Gauss-Newton method. Aspects of regularization and scaling are discussed. The model-based reconstruction was validated for a numerical and experimental flow phantom and applied to real-time phase-contrast MRI of the human aorta for 10 healthy subjects and 2 patients. RESULTS: Under all conditions, and compared with a previously developed real-time flow MRI method, the proposed method yields quantitatively accurate phase-contrast maps (i.e., flow velocities) with improved spatial acuity, reduced phase noise and reduced streaking artifacts. CONCLUSION: This novel model-based reconstruction technique may become a new tool for clinical flow MRI in real time.