English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Conference Paper

Mapping the fragmentation of acetylene with femtosecond resolution pump probe at LCLS using 2, 3, and 4 particle coincidences.

MPS-Authors
/persons/resource/persons199023

Boll,  R.
Research Group of Structural Dynamics of (Bio)Chemical Systems, MPI for Biophysical Chemistry, Max Planck Society;

External Resource
No external resources are shared
Fulltext (public)

2364665.pdf
(Publisher version), 296KB

Supplementary Material (public)
There is no public supplementary material available
Citation

Liekhus-Schmalt, C., Tenney, I., Osipov, T., Bucksbaum, P. H., Petrovic, V. S., Belkacem, A., et al. (2014). Mapping the fragmentation of acetylene with femtosecond resolution pump probe at LCLS using 2, 3, and 4 particle coincidences. Journal of Optical Society of America, 106735.


Cite as: http://hdl.handle.net/11858/00-001M-0000-002C-01E0-0
Abstract
A three-layer delay line anode detector has been used in x-ray pump x-ray probe time-resolved measurement at LCLS. We used ~10 fs long pulses to initiate and probe ultrafast dynamics in the dication of acetylene. The dynamics are discerned from the temporal evolution of multi-particle coincidences.