Comparison of small animal CT contrast agents

MPG-Autoren
/persons/resource/persons197581

Schlichthaerle,  Thomas
Jungmann, Ralf / Molecular Imaging and Bionanotechnology, Max Planck Institute of Biochemistry, Max Planck Society;

Externe Ressourcen
Es sind keine externen Ressourcen hinterlegt
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Mannheim, J. G., Schlichthaerle, T., Kuebler, L., Quintanilla-Martinez, L., Kohlhofer, U., Kneilling, M., et al. (2016). Comparison of small animal CT contrast agents. Contrast Media & Molecular Imaging, 11(4), 272-284. doi:10.1002/cmmi.1689.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-002C-8C90-4
Zusammenfassung
Non-invasive in vivo small animal computed tomography (CT) imaging provides high resolution bone scans but cannot differentiate between soft tissues. For most applications injections of contrast agents (CAs) are necessary. Aim of this study was to uncover the advantages and disadvantages of commercially available CT CAs (ExiTron nano 12 000 and 6000, eXIA 160 and 160XL, Fenestra VC and LC) regarding their pharmacokinetics, toxicological side-effects and the influence of anesthesia on the biodistribution, based on an injection volume of 100 mu L/25 g body weight. The pharmacokinetics of the CAs were determined for up to five days. The CA-induced toxicological/physiological side-effects were evaluated by determining blood counts, liver enzymes, thyroxine and total protein values, pro-inflammatory mediators (messenger ribonucleic acid (mRNA)), histology and immunohistochemistry. ExiTron nano 12 000 and 6000 yielded a long-term contrast enhancement (CE) in the liver and spleen for up to five days. Some of the evaluated CAs did not show any CE at all. Anesthesia did not impair the CAs' biodistribution. The CAs differentially affected the body weight, blood counts, liver enzymes, thyroxine and total protein values. ExiTron nano 12 000 and 6000 induced histiocytes in the liver and spleen. Moreover, ExiTron nano 12 000 and eXIA 160 enhanced tumor necrosis factor (TNF) mRNA expression levels in the kidneys. Thus, we recommend ExiTron nano 12 000 and 6000 when multiple injections should be avoided. We recommend careful selection of the employed CA in order to achieve an acceptable CE in the organs of interest and to avoid influences on the animal physiology. Copyright (C) 2016 John Wiley & Sons, Ltd.