English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Poster

Dual-layered multi-channel B0 and RF coil setup for an improved shimming performance at 9.4 Tesla

MPS-Authors
/persons/resource/persons84405

Mirkes,  C
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84213

Shajan,  G
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons192852

Aghaeifar,  A
Max Planck Institute for Biological Cybernetics, Max Planck Society;
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84826

Zivkovic,  I
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons133443

Buckenmaier,  K
Max Planck Institute for Biological Cybernetics, Max Planck Society;
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84187

Scheffler,  K
Max Planck Institute for Biological Cybernetics, Max Planck Society;
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Mirkes, C., Shajan, G., Aghaeifar, A., Zivkovic, I., Buckenmaier, K., & Scheffler, K. (2017). Dual-layered multi-channel B0 and RF coil setup for an improved shimming performance at 9.4 Tesla. Poster presented at 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017), Honolulu, HI, USA.


Cite as: https://hdl.handle.net/21.11116/0000-0000-C4AF-E
Abstract
Multiple local shim coils can be used to improve the B0 homogeneity at ultra-high field. In this work, a dual-layered multi-channel B0 and RF coil setup is presented that allows a flexible design of the shim coil without influencing the RF performance. It is shown that a 16 channel B0 coil in combination with a standard 2nd order spherical harmonics (SH) shim system can achieve a higher degree of B0homogeneity than a 3rd order SH shim system in the case of whole-brain shimming.