English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Dried-droplet probe preparation on AnchorChip targets for navigating the acquisition of matrix-assisted laser desorption/ionization time-of-flight spectra by fluorescence of matrix/analyte crystals.

MPS-Authors
/persons/resource/persons219733

Thomas,  Henrik
Max Planck Institute of Molecular Cell Biology and Genetics, Max Planck Society;

/persons/resource/persons219229

Havlis,  Jan
Max Planck Institute of Molecular Cell Biology and Genetics, Max Planck Society;

/persons/resource/persons219534

Peychl,  Jan
Max Planck Institute of Molecular Cell Biology and Genetics, Max Planck Society;

/persons/resource/persons218972

Shevchenko,  Andrej
Max Planck Institute of Molecular Cell Biology and Genetics, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Thomas, H., Havlis, J., Peychl, J., & Shevchenko, A. (2004). Dried-droplet probe preparation on AnchorChip targets for navigating the acquisition of matrix-assisted laser desorption/ionization time-of-flight spectra by fluorescence of matrix/analyte crystals. Rapid Communications in Mass Spectrometry, 18(9), 923-930.


Cite as: https://hdl.handle.net/21.11116/0000-0001-122F-7
Abstract
We have developed a dried-droplet probe preparation method for peptide mass fingerprinting by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS), which uses AnchorChip targets and alpha-cyano-4-hydroxycinnamic acid (CHCA) as a matrix. Upon drying of a matrix and analyte mixture on the AnchorChip, salts and low molecular weight contaminants were pooled at the hydrophilic metal anchor, whereas 10-50 microm matrix/peptide crystals firmly adhered at the surface of a hydrophobic polymer and the entire target could be subsequently washed by submerging it in 5% formic acid for 2-3 min. Epifluorescence microscopy suggested that peptides were completely co-localized with CHCA crystals at the AnchorChip surface. Fluorescent images of the probes were of good contrast and were background-free, compared with images taken by a video camera built into the ion source. CHCA/peptide crystals were easy to recognize at the surface and peptide mass maps were acquired from them without further adjustment of the position of the laser beam. These crystals were remarkably stable towards the laser depletion and almost no matrix-related ions were typically observed in the low m/z region of peptide mass maps. The sensitivity of the peptide mass mapping was at the low-femtomole level.