English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

MINFLUX monitors rapid molecular jumps with superior spatiotemporal resolution.

MPS-Authors
/persons/resource/persons203341

Eilers,  Y.
Department of NanoBiophotonics, MPI for Biophysical Chemistry, Max Planck Society;

/persons/resource/persons79571

Ta,  H.
Department of NanoBiophotonics, MPI for Biophysical Chemistry, Max Planck Society;

/persons/resource/persons96528

Gwosch,  K.
Department of NanoBiophotonics, MPI for Biophysical Chemistry, Max Planck Society;

/persons/resource/persons141819

Balzarotti,  F.
Department of NanoBiophotonics, MPI for Biophysical Chemistry, Max Planck Society;

/persons/resource/persons15210

Hell,  S. W.
Department of NanoBiophotonics, MPI for Biophysical Chemistry, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)

2596590.pdf
(Publisher version), 2MB

Supplementary Material (public)

2596590_Suppl.htm
(Supplementary material), 222KB

Citation

Eilers, Y., Ta, H., Gwosch, K., Balzarotti, F., & Hell, S. W. (2018). MINFLUX monitors rapid molecular jumps with superior spatiotemporal resolution. Proceedings of the National Academy of Sciences of the United States of America, 115(24), 6117-6122. doi:10.1073/pnas.1801672115.


Cite as: https://hdl.handle.net/21.11116/0000-0001-6965-8
Abstract
Compared with localization schemes solely based on evaluating patterns of molecular emission, the recently introduced single-molecule localization concept called MINFLUX and the fluorescence nanoscopies derived from it require up to orders of magnitude fewer emissions to attain single-digit nanometer resolution. Here, we demonstrate that the lower number of required fluorescence photons enables MINFLUX to detect molecular movements of a few nanometers at a temporal sampling of well below 1 millisecond. Using fluorophores attached to thermally fluctuating DNA strands as model systems, we demonstrate that measurement times as short as 400 microseconds suffice to localize fluorescent molecules with ∼2-nm precision. Such performance is out of reach for popular camera-based localization by centroid calculation of emission diffraction patterns. Since theoretical limits have not been reached, our results show that emerging MINFLUX nanoscopy bears great potential for dissecting the motions of individual (macro)molecules at hitherto-unattained combinations of spatial and temporal resolution.