English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Calibrated flow reactor to determine reaction rates: CO–oxidation on Pd(110)

MPS-Authors
/persons/resource/persons211638

Grunze,  M.
Cellular Biophysics, Max Planck Institute for Medical Research, Max Planck Society;

Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Goschnick, J., & Grunze, M. (1981). Calibrated flow reactor to determine reaction rates: CO–oxidation on Pd(110). Journal of Vacuum Science and Technology, 18(2), 561-565. doi:10.1116/1.570812.


Cite as: https://hdl.handle.net/21.11116/0000-0001-782B-9
Abstract
We describe the construction and the principles of operation of a flow reactor designed to obtain reaction rates of heterogeneous reactions over a wide pressure range. In this communication we restrict the discussion to the low pressure region and demonstrate the performance of the apparatus with transient reaction studies for the CO‐oxidation reaction on Pd(110).