English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Erratum: Quality assessment of MEG-to-MRI coregistrations

MPS-Authors
/persons/resource/persons103108

Sonntag,  Hermann
Methods and Development Unit MEG and EEG: Signal Analysis and Modelling , MPI for Human Cognitive and Brain Sciences, Max Planck Society;

/persons/resource/persons19833

Maess,  Burkhard       
Methods and Development Unit MEG and EEG: Signal Analysis and Modelling , MPI for Human Cognitive and Brain Sciences, Max Planck Society;

External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Sonntag, H., Haueisen, J., & Maess, B. (2018). Erratum: Quality assessment of MEG-to-MRI coregistrations. Physics in Medicine and Biology, 63(10): 109601. doi:10.1088/1361-6560/aabf4e.


Cite as: https://hdl.handle.net/21.11116/0000-0001-795C-1
Abstract
For high precision in source reconstruction of magnetoencephalography (MEG) or electroencephalography data, high accuracy of the coregistration of sources and sensors is mandatory. Usually, the source space is derived from magnetic resonance imaging (MRI). In most cases, however, no quality assessment is reported for sensor-to-MRI coregistrations. If any, typically root mean squares (RMS) of point residuals are provided. It has been shown, however, that RMS of residuals do not correlate with coregistration errors. We suggest using target registration error (TRE) as criterion for the quality of sensor-to-MRI coregistrations. TRE measures the effect of uncertainty in coregistrations at all points of interest. In total, 5544 data sets with sensor-to-head and 128 head-to-MRI coregistrations, from a single MEG laboratory, were analyzed. An adaptive Metropolis algorithm was used to estimate the optimal coregistration and to sample the coregistration parameters (rotation and translation). We found an average TRE between 1.3 and 2.3 mm at the head surface. Further, we observed a mean absolute difference in coregistration parameters between the Metropolis and iterative closest point algorithm of $(1.9 \pm 15){\hspace{0pt}}^{\circ}$ and $(1.1 \pm 9)$ m. A paired sample t-test indicated a significant improvement in goal function minimization by using the Metropolis algorithm. The sampled parameters allowed computation of TRE on the entire grid of the MRI volume. Hence, we recommend the Metropolis algorithm for head-to-MRI coregistrations.