English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Poster

A true comparison of B0 shimming with a very high order spherical harmonic based setup and a multicoil shim array

MPS-Authors
/persons/resource/persons192852

Aghaeifar,  A
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons192839

Chang,  P
Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons192740

Nassirpour,  S
Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons133452

Eschelbach,  M
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84402

Henning,  A
Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84187

Scheffler,  K
Max Planck Institute for Biological Cybernetics, Max Planck Society;
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Aghaeifar, A., Chang, P., Nassirpour, S., Eschelbach, M., Henning, A., & Scheffler, K. (2018). A true comparison of B0 shimming with a very high order spherical harmonic based setup and a multicoil shim array. Poster presented at Joint Annual Meeting ISMRM-ESMRMB 2018, Paris, France.


Cite as: https://hdl.handle.net/21.11116/0000-0001-828A-0
Abstract
In this work, a true experimental comparison between a very high order spherical harmonic based shim setup and a multi-coil shim array is presented. Each technique has its own cons and pros which are studied through several often-used sequences. All evaluations are performed by shimming of the human brain at 9.4T.