English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Poster

Spillover correction for quantification of pulsed-CEST experiments

MPS-Authors
There are no MPG-Authors in the publication available
External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Zaiss, M., Ivchenko, O., & Bachert, P. (2012). Spillover correction for quantification of pulsed-CEST experiments. Poster presented at 20th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2012), Melbourne, Australia.


Cite as: https://hdl.handle.net/21.11116/0000-0001-9EF7-7
Abstract
Chemical exchange saturation transfer (CEST) effect of endogenous CEST agents with small frequency offset from water resonance like amide protons (APT) are always diluted by direct saturation of water protons (spillover effect). An analytical spillover correction is presented which allows reconstructing the unperturbed pulsed-proton transfer rate for different flip angles and B1 using only label and reference scan. Additionally, the artificial pulsed-proton transfer rate is shown to be correlated with the analytical cw proton transfer rate. Therefore, the spillover correction provides analytic quantification of pulsed saturation transfer experiments which are feasible in clinical scanners.