English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Decoupling of a double‐row 16‐element tight‐fit transceiver phased array for human whole‐brain imaging at 9.4 T

MPS-Authors
/persons/resource/persons133464

Avdievich,  N
Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons192635

Giapitzakis,  IA
Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons192811

Pfrommer,  A
Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84213

Shajan,  G
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84187

Scheffler,  K
Max Planck Institute for Biological Cybernetics, Max Planck Society;
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84402

Henning,  A
Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Avdievich, N., Giapitzakis, I., Pfrommer, A., Shajan, G., Scheffler, K., & Henning, A. (2018). Decoupling of a double‐row 16‐element tight‐fit transceiver phased array for human whole‐brain imaging at 9.4 T. NMR in Biomedicine, 31(9), 1-13. doi:10.1002/nbm.3964.


Cite as: https://hdl.handle.net/21.11116/0000-0001-A8D6-0
Abstract
One of the major challenges in constructing multi‐channel and multi‐row transmit (Tx) or transceiver (TxRx) arrays is the decoupling of the array's loop elements. Overlapping of the surface loops allows the decoupling of adjacent elements and also helps to improve the radiofrequency field profile by increasing the penetration depth and eliminating voids between the loops. This also simplifies the design by reducing the number of decoupling circuits. At the same time, overlapping may compromise decoupling by generating high resistive (electric) coupling near the overlap, which cannot be compensated for by common decoupling techniques. Previously, based on analytical modeling, we demonstrated that electric coupling has strong frequency and loading dependence, and, at 9.4 T, both the magnetic and electric coupling between two heavily loaded loops can be compensated at the same time simply by overlapping the loops. As a result, excellent decoupling was obtained between adjacent loops of an eight‐loop single‐row (1 × 8) human head tight‐fit TxRx array. In this work, we designed and constructed a 9.4‐T (400‐MHz) 16‐loop double‐row (2 × 8) overlapped TxRx head array based on the results of the analytical and numerical electromagnetic modeling. We demonstrated that, simply by the optimal overlap of array loops, a very good decoupling can be obtained without additional decoupling strategies. The constructed TxRx array provides whole‐brain coverage and approximately 1.5 times greater Tx efficiency relative to a transmit‐only/receive‐only (ToRo) array, which consists of a larger Tx‐only array and a nested tight‐fit 31‐loop receive (Rx)‐only array. At the same time, the ToRo array provides greater peripheral signal‐to‐noise ratio (SNR) and better Rx parallel performance in the head–feet direction. Overall, our work provides a recipe for a simple, robust and very Tx‐efficient design suitable for parallel transmission and whole‐brain imaging at ultra‐high fields.