English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Direct characterization of the evanescent field in objective-type total internal reflection fluorescence microscopy

MPS-Authors
/persons/resource/persons227403

Niederauer,  Christian
Schwille, Petra / Cellular and Molecular Biophysics, Max Planck Institute of Biochemistry, Max Planck Society;

/persons/resource/persons215565

Blumhardt,  Philipp
Schwille, Petra / Cellular and Molecular Biophysics, Max Planck Institute of Biochemistry, Max Planck Society;

/persons/resource/persons138355

Mücksch,  Jonas
Schwille, Petra / Cellular and Molecular Biophysics, Max Planck Institute of Biochemistry, Max Planck Society;

/persons/resource/persons197087

Heymann,  Michael
Schwille, Petra / Cellular and Molecular Biophysics, Max Planck Institute of Biochemistry, Max Planck Society;

/persons/resource/persons78294

Lambacher,  Armin
Fässler, Reinhard / Molecular Medicine, Max Planck Institute of Biochemistry, Max Planck Society;

/persons/resource/persons15815

Schwille,  Petra
Schwille, Petra / Cellular and Molecular Biophysics, Max Planck Institute of Biochemistry, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)

oe-26-16-20492.pdf
(Publisher version), 21MB

Supplementary Material (public)
There is no public supplementary material available
Citation

Niederauer, C., Blumhardt, P., Mücksch, J., Heymann, M., Lambacher, A., & Schwille, P. (2018). Direct characterization of the evanescent field in objective-type total internal reflection fluorescence microscopy. Optics Express, 26(16), 20492-20506. doi:10.1364/OE.26.020492.


Cite as: https://hdl.handle.net/21.11116/0000-0002-7877-2
Abstract
Total internal reflection fluorescence (TIRF) microscopy is a commonly used method for studying fluorescently labeled molecules in close proximity to a surface. Usually, the TIRF axial excitation profile is assumed to be single-exponential with a characteristic penetration depth, governed by the incident angle of the excitation laser beam towards the optical axis. However, in practice, the excitation profile does not only comprise the theoretically predicted single-exponential evanescent field, but also an additional non-evanescent contribution, supposedly caused by scattering within the optical path or optical aberrations. We developed a calibration slide to directly characterize the TIRF excitation field. Our slide features ten height steps ranging from 25 to 550 nanometers, fabricated from a polymer with a refractive index matching that of water. Fluorophores in aqueous solution above the polymer step layers sample the excitation profile at different heights. The obtained excitation profiles confirm the theoretically predicted exponential decay over increasing step heights as well as the presence of a non-evanescent contribution. (c) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement