日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細


公開

ポスター

Prediction and correction of physiological noise in fMRI using machine learning

MPS-Authors
There are no MPG-Authors in the publication available
External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
フルテキスト (公開)
公開されているフルテキストはありません
付随資料 (公開)
There is no public supplementary material available
引用

Ash, T., Suckling, J., Walter, M., Ooi, C., Tempelmann, C., Carpenter, A., & Williams, G. (2011). Prediction and correction of physiological noise in fMRI using machine learning. Poster presented at 19th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2011), Montréal, Canada.


引用: https://hdl.handle.net/21.11116/0000-0002-4C3C-7
要旨
We present a support vector machine based technique for recreation of partially or fully absent physiological recording data, to allow detrending of physiological noise to occur even in the absence of complete recordings of the physiological cycles. The technique uses a multi-class SVM to predict phase of each physiological cycle from fMRI image data, after training on prior data. Using these predicted phase values as inputs to physiological detrending tool RETROICOR show similar impact on Fourier transforms of the data as using recorded values, showing that they are accurate enough for use as inputs to detrending tools.