English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Poster

Comparison of 2 Different Tumor Cell Labeling Techniques for in Vitro MRI Characterization with New Iron Oxide Particles

MPS-Authors
There are no MPG-Authors in the publication available
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Saborowski, O., Santini, F., Fani, M., Robert, P., Ballet, S., Raynaud, J., et al. (2008). Comparison of 2 Different Tumor Cell Labeling Techniques for in Vitro MRI Characterization with New Iron Oxide Particles. Poster presented at 16th Scientific Meeting and Exhibition of the International Society of Magnetic Resonance in Medicine (ISMRM 2008), Toronto, Canada.


Cite as: https://hdl.handle.net/21.11116/0000-0003-9330-0
Abstract
Iron oxide particles (SPIO and USPIO) are widely used for MRI-based cell labeling and tracking because they can be loaded on cells by simple protocols
and provide high image contrast due to their large susceptibility effect. We compared 2 different cell labeling models (AGAR and Ficoll) in human KB cells.
Both presented cell labeling methods (AGAR and Ficoll model) are feasible for in vitro MR characterization of KB tumor cells at 1.5, 2.35 and 3T. Ficoll
method is easier to perform because it does not need a heating procedure for preparation without air bubbles as compared to AGAR method.