English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Poster

Improvement of R2* mapping in Alzheimer’s Disease at 9.4T through reduction of B0 fluctuation-induced image artifacts using Navigator Echoes

MPS-Authors
/persons/resource/persons214563

Tuzzi,  E
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons83952

Hagberg,  G
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84372

Loktyushin,  A
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84145

Pohmann,  R
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84187

Scheffler,  K
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Tuzzi, E., Hagberg, G., Loktyushin, A., Pohmann, R., Zeller, A., Laske, C., et al. (2019). Improvement of R2* mapping in Alzheimer’s Disease at 9.4T through reduction of B0 fluctuation-induced image artifacts using Navigator Echoes. Poster presented at 27th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2019), Montréal, QC, Canada.


Cite as: https://hdl.handle.net/21.11116/0000-0003-9709-9
Abstract
Ultra-High-Field (UHF) MRI provides a potential non-invasive means to investigate Alzheimer’s Disease (AD). R2* map is one of the most established MRI techniques to detect iron concentration in the brain. However, image quality can be substantially affected by B0 fluctuation-related-artifacts at UHF. In this study we showed an improvement of the quality of R2* maps in AD at 9.4T using Navigator Echos approach.