English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Intramyocellular lipid quantification from 1H long echo time spectra at 1.5 and 3 T by means of the LCModel technique

MPS-Authors
There are no MPG-Authors in the publication available
External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Škoch, A., Jírů, F., Dezortová, M., Krušinová, E., Kratochvílová, S., Pelikánová, T., et al. (2006). Intramyocellular lipid quantification from 1H long echo time spectra at 1.5 and 3 T by means of the LCModel technique. Journal of Magnetic Resonance Imaging, 23(5), 728-735. doi:10.1002/jmri.20574.


Cite as: https://hdl.handle.net/21.11116/0000-0004-8430-0
Abstract
PURPOSE:

To introduce a method of independent determination of CH2 and CH3 components of intramyocellular lipids (IMCLs) by using long TE for spectra measurement and LCModel for spectra evaluation, to test this technique in controls and insulin-resistant subjects, and to compare results at 1.5 and 3 T.
MATERIALS AND METHODS:

Eight healthy volunteers and 11 patients with type 2 diabetes mellitus underwent measurement using a 1.5-T MR scanner; six healthy volunteers were measured using a 3-T MR scanner. Spectra from the tibialis anterior muscle were acquired by using a point resolved spectroscopy (PRESS) sequence with the following parameters: TR/TE/ACQ = 2000 msec/270 msec/256. Spectra were processed by LCModel 6.1 software with two types of adopted basis-set.
RESULTS:

Spectra with good separation of both CH2 and CH3 components of IMCL and extramyocellular lipids (EMCLs) were obtained and the LCModel routine was successfully applied. The reproducibility comparison (N= 7 at 1.5 T vs. N = 5 at 3 T) showed that better results can be obtained at higher B0 values. The comparison of the healthy and insulin-resistant subjects proved that both IMCL_CH2/Cr and IMCL_CH3/Cr ratios significantly differ.
CONCLUSION:

Long TE spectroscopy of the human muscle with IMCL quantification using the LCModel technique can detect changes in IMCL levels as well as help in the study of fatty acyl chain composition. Using a higher field strength increased the intra-individual reproducibility by approximately 150%.