English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Poster

Detecting fat artifacts in diffusion MRI with deep learning

MPS-Authors
/persons/resource/persons213892

Podranski,  Kornelius
Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society;

/persons/resource/persons198968

Zhang,  Rui
Department Neurology, MPI for Human Cognitive and Brain Sciences, Max Planck Society;

/persons/resource/persons226758

Thierbach,  Konstantin
Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society;

/persons/resource/persons225377

Thieleking,  Ronja
Department Neurology, MPI for Human Cognitive and Brain Sciences, Max Planck Society;

/persons/resource/persons128137

Witte,  A. Veronica
Department Neurology, MPI for Human Cognitive and Brain Sciences, Max Planck Society;

/persons/resource/persons20065

Villringer,  Arno
Department Neurology, MPI for Human Cognitive and Brain Sciences, Max Planck Society;

/persons/resource/persons147461

Weiskopf,  Nikolaus
Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society;

/persons/resource/persons201756

Scherf,  Nico
Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Podranski, K., Zhang, R., Thierbach, K., Thieleking, R., Witte, A. V., Villringer, A., et al. (2019). Detecting fat artifacts in diffusion MRI with deep learning. Poster presented at 9th IMPRS NeuroCom Summer School, Leipzig, Germany.


Cite as: https://hdl.handle.net/21.11116/0000-0004-C6C1-2
Abstract
Sometimes magnetic resonance imaging (MRI) data is distorted by severe artifacts, due to non optimal sequence settings. Analyses of those images are going to produce false results and will confound affected studies. For that reason it is important to detect and remove datasets containing artifacts. Manual quality control of all images in large cohorts is not feasible; automatic methods to detect relevant artifacts are needed.
We trained a fully convolutional feed forward network to detect artifacts caused by imperfect fat suppression in MRI diffusion measurements (DWI) of the human head (128x128x72@1.7mm³/voxel, 60 diffusion directions, b=1000 s/mm²). The deep neural network was pre-trained for two epochs on an auto-encoding task using one million unlabeled slices from 2000 different DWI datasets. After pre-training the encoder was separated and extended with one additional layer. The prediction task was trained on 1200 labeled slices from 100 different DWI datasets with binary cross-entropy objective. The optimal training state was selected posterior based on the best accuracy.
Inference on 3303 before unseen slices achieved an accuracy of 0.82 (true positives: 179, true negatives: 2537, false positives: 26, false negatives: 561).
Exploration of misclassified images often showed positive response to very bright spots and negative response if the contrast between artifact and surrounding voxels was low.
Considering, that only few labels were available the achieved results are very promising. Predicting several slices for each dataset and applying majority voting might be used to further reduce false predictions.