English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Proceedings

The calibration procedure of the LINC-NIRVANA ground and high layer WFS

MPS-Authors

Arcidiacono,  Carmelo
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Santhakumari,  Kalyan Kumar R.
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Viotto,  Valentina
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Bergomi,  Maria
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Briegel,  Florian
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Bertram,  Thomas
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Marafatto,  Luca
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Herbst,  Tom
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Farinato,  Jacopo
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Ragazzoni,  Roberto
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Hofferbert,  Ralph
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Kürster,  Martin
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Kittmann,  Frank
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Berwein,  Jürgen
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Baumeister,  Harald
Max Planck Institute for Astronomy, Max Planck Society and Cooperation Partners;

Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Arcidiacono, C., Santhakumari, K. K. R., Viotto, V., Bergomi, M., Briegel, F., Bertram, T., et al. (2018). The calibration procedure of the LINC-NIRVANA ground and high layer WFS.


Cite as: https://hdl.handle.net/21.11116/0000-0005-CF34-8
Abstract
LINC-NIRVANA (LN) is a MCAO module currently mounted on the Rear Bent Gregorian focus of the Large Binocular Telescope (LBT). It mounts a camera originally design to realize the interferometric imaging focal station of the LBT. LN follows the LBT strategy having two twin channels: a double Layer Oriented multi-conjugate adaptive optics system assists the two arms, supplying high order wave-front correction. In order to counterbalance the field rotation a mechanical derotation is applied for the two ground wave-front sensors, and an optical (K-mirror) one for the two high layers sensors, fixing the positions of the focal planes with respect to the pyramids aboard the wavefront sensors. The derotation introduces a pupil images rotation on the wavefront sensors changing the projection of the deformable mirrors on the sensor consequently. The soft real-time computer load the matrix corresponding to the needed at one degree step. Calibrations were performed in daytime only and using optical fibers.