Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

The Preparation and Preliminary Characterisation of Three Synthetic Andesite Reference Glass Materials (ARM-1, ARM-2, ARM-3) for In Situ Microanalysis

MPG-Autoren
/persons/resource/persons101034

Jochum,  Klaus P.
Climate Geochemistry, Max Planck Institute for Chemistry, Max Planck Society;

/persons/resource/persons101291

Stoll,  Brigitte
Climate Geochemistry, Max Planck Institute for Chemistry, Max Planck Society;

Externe Ressourcen
Es sind keine externen Ressourcen hinterlegt
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Wu, S., Worner, G., Jochum, K. P., Stoll, B., Simon, K., & Kronz, A. (2019). The Preparation and Preliminary Characterisation of Three Synthetic Andesite Reference Glass Materials (ARM-1, ARM-2, ARM-3) for In Situ Microanalysis. Geostandards and Geoanalytical Research, 43(4), 567-584. doi:10.1111/ggr.12301.


Zitierlink: https://hdl.handle.net/21.11116/0000-0005-F0B4-0
Zusammenfassung
Three synthetic reference glasses were prepared by directly fusing and stirring 3.8 kg of high-purity oxide powders to provide reference materials for microanalytical work. These glasses have andesitic major compositions and are doped with fifty-four trace elements in nearly identical abundance (500, 50, 5 mu µg g−1) using oxide powders or element solutions, and are named ARM-1, 2 and 3, respectively. We further document that sector-field (SF) ICP-MS (Element 2 or Element XR) is capable of sweeping seventy-seven isotopes (from 7Li to 238U, a total of sixty-eight elements) in 1 s and, thus, is able to quantify up to sixty-eight elements by laser sampling. Micro- and bulk analyses indicate that the glasses are homogeneous with respect to major and trace elements. This paper provides preliminary data for the ARM glasses using a variety of analytical techniques (EPMA, XRF, ICP-OES, ICP-MS, LA-Q-ICP-MS and LA-SF-ICP-MS) performed in ten laboratories. Discrepancies in the data of V, Cr, Ni and Tl exist, mainly caused by analytical limitations. Preliminary reference and information values for fifty-six elements were calculated with uncertainties [2 relative standard error (RSE)] estimated in the range of 1-20%.