English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Plate-height model of ion mobility-mass spectrometry: Part 2-Peak-to-peak resolution and peak capacity

MPS-Authors
/persons/resource/persons213543

Grabarics,  Márkó
Institute of Chemistry and Biochemistry, Freie Universität Berlin;
Molecular Physics, Fritz Haber Institute, Max Planck Society;

/persons/resource/persons221551

Lettow,  Maike
Institute of Chemistry and Biochemistry, Freie Universität Berlin;
Molecular Physics, Fritz Haber Institute, Max Planck Society;

/persons/resource/persons21614

Helden,  Gert von
Molecular Physics, Fritz Haber Institute, Max Planck Society;

/persons/resource/persons32738

Pagel,  Kevin
Institute of Chemistry and Biochemistry, Freie Universität Berlin;
Molecular Physics, Fritz Haber Institute, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)

jssc.202100201.pdf
(Publisher version), 4MB

Supplementary Material (public)
There is no public supplementary material available
Citation

Grabarics, M., Lettow, M., Kirk, A. T., Helden, G. v., Causon, T. J., & Pagel, K. (2021). Plate-height model of ion mobility-mass spectrometry: Part 2-Peak-to-peak resolution and peak capacity. Journal of Separation Science, 44(14), 2798-2813. doi:10.1002/jssc.202100201.


Cite as: https://hdl.handle.net/21.11116/0000-0008-D58C-A
Abstract
In a previous work, we explored zone broadening and the achievable plate numbers in linear drift tube ion mobility-mass spectrometry through developing a plate-height model [1]. On the basis of these findings, the present theoretical study extends the model by exploring peak-to-peak resolution and peak capacity in ion mobility separations. The first part provides a critical overview of chromatography-influenced resolution equations, including refinement of existing formulae. Furthermore, we present exact resolution equations for drift tube ion mobility spectrometry based on first principles. Upon implementing simple modifications, these exact formulae could be readily extended to traveling wave ion mobility separations and to cases when ion mobility spectrometry is coupled to mass spectrometry. The second part focuses on peak capacity. The well-known assumptions of constant plate number and constant peak width form the basis of existing approximate solutions. To overcome their limitations, an exact peak capacity equation is derived for drift tube ion mobility spectrometry. This exact solution is rooted in a suitable physical model of peak broadening, accounting for the finite injection pulse and subsequent diffusional spreading. By borrowing concepts from the theoretical toolbox of chromatography, we believe that the present study will help in integrating ion mobility spectrometry into the unified language of separation science.