English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Comparison of ESI-MS/MS and APCI-MS methods for the quantification of folic acid analogs in C. elegans

MPS-Authors
/persons/resource/persons277995

Annibal,  A.
Department Antebi - Molecular Genetics of Ageing, Max Planck Institute for Biology of Ageing, Max Planck Society;

/persons/resource/persons278004

Tam,  H.
Department Antebi - Molecular Genetics of Ageing, Max Planck Institute for Biology of Ageing, Max Planck Society;

/persons/resource/persons130926

Latza,  C.
Department Antebi - Molecular Genetics of Ageing, Max Planck Institute for Biology of Ageing, Max Planck Society;

/persons/resource/persons50070

Antebi,  A.
Department Antebi - Molecular Genetics of Ageing, Max Planck Institute for Biology of Ageing, Max Planck Society;

External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Annibal, A., Tam, H., Latza, C., & Antebi, A. (2019). Comparison of ESI-MS/MS and APCI-MS methods for the quantification of folic acid analogs in C. elegans. J Mass Spectrom, 54(4), 316-327. doi:10.1002/jms.4337.


Cite as: https://hdl.handle.net/21.11116/0000-000B-4328-D
Abstract
Folic acid (FA) plays a vital role in central metabolism, including the one carbon cycle, nucleotide, and amino acid biosynthesis. The development of sensitive, accurate analytical methods to measure FA intermediates in tissues is critical to understand their biological roles in diverse physiological and pathological contexts. Here, we developed a highly sensitive method for the simultaneous quantification of FA intermediates in the nematode Caenorhabditis elegans as a model to dissect metabolic networks. The method was further validated by analyzing the worm folate pool upon RNAi knockdown of the dihydrofolate reductase gene dhfr-1. Comparative mass spectrometry behavior of the FA analogs using two different ion sources, electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), revealed ESI-MS/MS to be more sensitive, but APCI-MS provided more detailed structure inferences, which can elucidate chemical investigation and synthesis of FA analogs. Finally, we report on the use of in vitro oxidation coupled with high-resolution mass spectrometry as a tool to discover new endogenous FA derivatives in the nematode.