日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細


公開

学術論文

LaCaMnO3 thin film laser energy/power meter

MPS-Authors
/persons/resource/persons280716

Zhang,  P. X.
Scientific Facility Thin Film Technology (Gennady Logvenov), Max Planck Institute for Solid State Research, Max Planck Society;
Scientific Facility Crystal Growth (Masahiko Isobe), Max Planck Institute for Solid State Research, Max Planck Society;

/persons/resource/persons280635

Wang,  C.
Department Physical Chemistry of Solids (Joachim Maier), Max Planck Institute for Solid State Research, Max Planck Society;

/persons/resource/persons280711

Zhang,  G. Y.
Scientific Facility Crystal Growth (Masahiko Isobe), Max Planck Institute for Solid State Research, Max Planck Society;

/persons/resource/persons280695

Yu,  L.
Department Solid State Spectroscopy (Bernhard Keimer), Max Planck Institute for Solid State Research, Max Planck Society;
Scientific Facility Thin Film Technology (Gennady Logvenov), Max Planck Institute for Solid State Research, Max Planck Society;

/persons/resource/persons280017

Habermeier,  H.-U.
Scientific Facility Thin Film Technology (Gennady Logvenov), Max Planck Institute for Solid State Research, Max Planck Society;
Department Solid State Spectroscopy (Bernhard Keimer), Max Planck Institute for Solid State Research, Max Planck Society;
Department Physical Chemistry of Solids (Joachim Maier), Max Planck Institute for Solid State Research, Max Planck Society;

External Resource
There are no locators available
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
フルテキスト (公開)
公開されているフルテキストはありません
付随資料 (公開)
There is no public supplementary material available
引用

Zhang, P. X., Wang, C., Zhang, G. Y., Yu, L., Lee, W. K., & Habermeier, H.-U. (2004). LaCaMnO3 thin film laser energy/power meter. Optics & Laser Technology, 36(4), 341-343.


引用: https://hdl.handle.net/21.11116/0000-000E-FB23-0
要旨
A prototype laser energy/power meter was designed based on the
anisotropic Seebeck effect of LaCaMnO3 thin film grown on vicinal cut
LaAlO3 substrate. The optical response of this device to the pulsed
laser and the chopped CW laser was measured from infrared to
ultraviolet. The peak voltage of the measured signal shows a good
linear relation to the laser energy and power in the measured range. It
was shown that at 1064 nm wavelength, this prototype device
demonstrates higher sensitivity than that of commercial device. (C)