English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Current Approaches for Image Fusion of Histological Data with Computed Tomography and Magnetic Resonance Imaging

MPS-Authors
/persons/resource/persons221404

Dullin,  Christian
Research Group of Translational Molecular Imaging, Max Planck Institute for Multidisciplinary Sciences, Max Planck Society;

/persons/resource/persons182068

Alves,  Frauke
Research Group of Translational Molecular Imaging, Max Planck Institute for Multidisciplinary Sciences, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)

6765895.pdf
(Publisher version), 4MB

Supplementary Material (public)
There is no public supplementary material available
Citation

Nolte, P., Dullin, C., Svetlove, A., Brettmacher, M., Russmann, C., Schilling, A. F., et al. (2022). Current Approaches for Image Fusion of Histological Data with Computed Tomography and Magnetic Resonance Imaging. Radiology Research and Practice, 2022: 6765895. doi:10.1155/2022/6765895.


Cite as: https://hdl.handle.net/21.11116/0000-000C-03D2-3
Abstract
Classical analysis of biological samples requires the destruction of the tissue’s integrity by cutting or grinding it down to thin slices for (Immuno)-histochemical staining and microscopic analysis. Despite high specificity, encoded in the stained 2D section of the whole tissue, the structural information, especially 3D information, is limited. Computed tomography (CT) or magnetic resonance imaging (MRI) scans performed prior to sectioning in combination with image registration algorithms provide an opportunity to regain access to morphological characteristics as well as to relate histological findings to the 3D structure of the local tissue environment. This review provides a summary of prevalent literature addressing the problem of multimodal coregistration of hard- and soft-tissue in microscopy and tomography. Grouped according to the complexity of the dimensions, including image-to-volume (2D ⟶ 3D), image-to-image (2D ⟶ 2D), and volume-to-volume (3D ⟶ 3D), selected currently applied approaches are investigated by comparing the method accuracy with respect to the limiting resolution of the tomography. Correlation of multimodal imaging could position itself as a useful tool allowing for precise histological diagnostic and allow the a priori planning of tissue extraction like biopsies.