日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細


公開

学術論文

Effective thermal conductivity of dimagnesium iron hexahydride (Mg2FeH6) for heat storage applications

MPS-Authors
/persons/resource/persons238093

Albert,  Rene
Research Group Felderhoff, Max-Planck-Institut für Kohlenforschung, Max Planck Society;

/persons/resource/persons286086

Wagner,  Christian
Research Group Felderhoff, Max-Planck-Institut für Kohlenforschung, Max Planck Society;

/persons/resource/persons136051

Urbanczyk,  Robert
Research Group Felderhoff, Max-Planck-Institut für Kohlenforschung, Max Planck Society;
Institut für Energie- und Umwelttechnik e. V. (IUTA e. V,);

/persons/resource/persons58541

Felderhoff,  Michael
Research Group Felderhoff, Max-Planck-Institut für Kohlenforschung, Max Planck Society;

External Resource
There are no locators available
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
フルテキスト (公開)
公開されているフルテキストはありません
付随資料 (公開)
There is no public supplementary material available
引用

Albert, R., Wagner, C., Urbanczyk, R., & Felderhoff, M. (2023). Effective thermal conductivity of dimagnesium iron hexahydride (Mg2FeH6) for heat storage applications. Applied Physics A, 129(1):. doi:10.1007/s00339-022-06336-9.


引用: https://hdl.handle.net/21.11116/0000-000C-8263-1
要旨
The transient plane source method was applied to measure the effective thermal conductivity in dimagnesium iron hexahydride (Mg2FeH6) prepared in a high-pressure synthesis of 50 temperature-driven de-/hydrogenation cycles. Temperature- and pressure-dependent measurements of the effective thermal conductivity of the as-synthesized Mg2FeH6 powder have been performed. Measurements for as synthesized Mg2FeH6 were carried out between 2 and 100 bar in a temperature range from 50 °C to 300 °C and at 70 bar in a temperature range from 480 °C to 520 °C during the cycle test. The effective thermal conductivity of the as-synthesized Mg2FeH6 varied between 0.39 W m−1 K−1, recorded at 50 °C and 2 bar of hydrogen gas pressure, and 0.54 W m−1 K−1, measured at 300 °C and 100 bar hydrogen pressure. The effective thermal conductivity increased with elevated hydrogen gas pressure and temperature. An evidence was found that the presence of iron prevents the sintering of the powder, resulting in a constant effective thermal conductivity during all accomplished cycles. The advantage of a non-sintered material resulting in higher hydrogen diffusion, which leads to a faster reaction time. For 50 measured de-/hydrogenation cycles between 480 °C and 520 °C, the thermal conductivity was found to be constant at around ~ 1.0 W m−1 K−1 in the dehydrogenated state (70 bar/520 °C) and between 0.7 W m−1 K−1 and 0.8 W m−1 K−1 in the hydrogenated state (70 bar/480 °C).