Puchnin, V., Jandaliyeva, A., Hurshkainen, A., Solomakha, G., Nikulin, A., Petrova, P., et al. (2023). Quadrature transceive wireless coil: Design concept and application for bilateral breast MRI at 1.5 T. Magnetic Resonance in Medicine, 89(3), 1251-1264. doi:10.1002/mrm.29507.


Cite as: https://hdl.handle.net/21.11116/0000-000C-AA1A-8
Abstract
Purpose: Development of a novel quadrature inductively driven transceive wireless coil for breast MRI at 1.5 T.
Methods: A quadrature wireless coil (HHMM-coil) design has been developed as a combination of two linearly polarized coils: a pair of 'metasolenoid' coils (MM-coil) and a pair of Helmholtz-type coils (HH-coil). The MM-coil consisted of an array of split-loop resonators. The HH-coil design included two electrically connected flat spirals. All the wireless coils were coupled to a whole-body birdcage coil. The HHMM-coil was studied and compared to the linear coils in terms of transmit and SAR efficiencies via numerical simulations. A prototype of HHMM-coil was built and tested on a 1.5 T scanner in a phantom and healthy volunteer. We also proposed an extended design of the HHMM-coil and compared its performance to a dedicated breast array.
Results: Numerical simulations of the HHMM-coil with a female voxel model have shown more than a 2.5-fold increase in transmit efficiency and a 1.7-fold enhancement of SAR efficiency compared to the linearly polarized coils. Phantom and in vivo imaging showed good agreement with the numerical simulations. Moreover, the HHMM-coil provided good image quality, visualizing all areas of interest similar to a multichannel breast array with a 32% reduction in signal-to-noise ratio.
Conclusion: The proposed quadrature HHMM-coil allows the B+1
-field to be significantly better focused in the region-of-interest compared to the linearly polarized coils. Thus, the HHMM-coil provides high-quality breast imaging on a 1.5 T scanner using a whole-body birdcage coil for transmit and receive.