Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

Size-dependent hygroscopicity of levoglucosan and D-glucose aerosol nanoparticles

MPG-Autoren
/persons/resource/persons217437

Lei,  Ting
Multiphase Chemistry, Max Planck Institute for Chemistry, Max Planck Society;

/persons/resource/persons101295

Su,  Hang
Multiphase Chemistry, Max Planck Institute for Chemistry, Max Planck Society;

/persons/resource/persons101189

Pöschl,  Ulrich
Multiphase Chemistry, Max Planck Institute for Chemistry, Max Planck Society;

/persons/resource/persons127588

Cheng,  Yafang
Multiphase Chemistry, Max Planck Institute for Chemistry, Max Planck Society;

Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Lei, T., Su, H., Ma, N., Pöschl, U., Wiedensohler, A., & Cheng, Y. (2023). Size-dependent hygroscopicity of levoglucosan and D-glucose aerosol nanoparticles. Atmospheric Chemistry and Physics, 23(8), 4763-4774. doi:10.5194/acp-23-4763-2023.


Zitierlink: https://hdl.handle.net/21.11116/0000-000D-8C2C-5
Zusammenfassung
The interaction between water vapor and aerosol nanoparticles is important in atmospheric processes. Hygroscopicity of sub-10 nm organic nanoparticles and their concentration-dependent thermodynamic properties (e.g., water activity) in the highly supersaturated concentration range are, however, scarcely available. Here we investigate the size dependence of hygroscopicity of organics (i.e., levoglucosan, D-glucose) in dry particle diameter down to 6 nm using a nano-hygroscopicity tandem differential mobility analyzer (nano-HTDMA). Our results show that there is only weak size-dependent hygroscopic growth of both levoglucosan and D-glucose nanoparticles with diameters down to 20 nm. In the diameter range smaller than 20 nm (down to 6 nm), we observed strong size-dependent hygroscopic growth for D-glucose nanoparticles. The hygroscopic growth factors cannot be determined for levoglucosan below 20 nm due to its evaporation. In addition, we compare hygroscopicity measurements for levoglucosan and D-glucose nanoparticles with E-AIM (standard UNIFAC – functional group activity coefficients), the ideal solution theory, and differential Köhler analysis (DKA) predictions. The ideal solution theory describes the measured hygroscopic growth factors of levoglucosan with diameters down to 20 nm and D-glucose nanoparticles with diameters larger than 60 nm, while E-AIM (standard UNIFAC) can successfully predict the growth factors of D-glucose nanoparticles with diameters from 100 down to 6 nm at RH above 88 %–40 % (e.g., at RH above 88 % for 100 nm D-glucose, at RH above 40 % for 6 nm D-glucose). The use of the DKA method leads to good agreement with measured hygroscopic growth factors of D-glucose aerosol nanoparticles with diameters from 100 down to 6 nm. Predicted water activity for these aqueous organic solutions (i.e., levoglucosan, D-glucose) from different parameterization methods agrees well with observations in the low solute concentration range (< 20 mol kg−1) and starts to deviate from observations in the high solute concentration (> 20 mol kg−1).