English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

First measurements of remoTES cryogenic calorimeters: Easy-to-fabricate particle detectors for a wide choice of target materials

MPS-Authors

Angloher,  G.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Bharadwaj,  M.R.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Dafinei,  I.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Di Marco,  N.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Einfalt,  L.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Ferroni,  F.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Fichtinger,  S.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Filipponi,  A.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Frank,  T.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Friedl,  M.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Fuss,  A.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Ge,  Z.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Heikinheimo,  M.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Huitu,  K.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Kellermann,  M.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Maji,  R.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Mancuso,  M.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Pagnanini,  L.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Petricca,  F.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Pirro,  S.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Proebst,  F.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Profeta,  G.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Puiu,  A.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Reindl,  F.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Schaeffner,  K.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Schieck,  J.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Schmiedmayer,  D.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Schwertner,  C.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Stahlberg,  M.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Stendahl,  A.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Wagner,  F.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Yue,  S.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Zema,  V.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Zhu,  Y.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Bento,  A.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Canonica,  L.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Garai,  A.
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Angloher, G., Bharadwaj, M., Dafinei, I., Di Marco, N., Einfalt, L., Ferroni, F., et al. (2023). First measurements of remoTES cryogenic calorimeters: Easy-to-fabricate particle detectors for a wide choice of target materials. Nuclear Instruments and Methods in Physics Research Section A, 1045, 167532. doi:10.1016/j.nima.2022.167532.


Cite as: https://hdl.handle.net/21.11116/0000-000F-1194-6
Abstract
Low-temperature calorimeters based on a readout via Transition Edge Sensors (TESs) and operated below 100 mK are well suited for rare event searches with outstanding resolution and low thresholds. We present first experimental results from two detector prototypes using a novel design of the thermometer coupling denoted remoTES, which further extends the applicability of the TES technology by including a wider class of potential absorber materials. In particular, this design facilitates the use of materials whose physical and chemical properties, as e.g. hygroscopicity, low hardness and low melting point, prevent the direct fabrication of the TES onto their surface. This is especially relevant in the context of the COSINUS experiment (Cryogenic Observatory for SIgnals seen in Next-Generation Underground Searches), where sodium iodide (NaI) is used as absorber material. With two remoTES prototype detectors operated in an above-ground R&D facility, we achieve energy resolutions of σ=87.8 eV for a 2.33 g silicon absorber and σ=193.5 eV for a 2.27 g α-TeO2 absorber, respectively. RemoTES calorimeters offer - besides the wider choice of absorber materials - a simpler production process combined with a higher reproducibility for large detector arrays and an enhanced radiopurity standard.