English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Calorimeter calibration of the ComPol CubeSat gamma-ray polarimeter

MPS-Authors

Cojocari,  Ion
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Meier,  Matthias
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Laurent,  Philippe
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Laviron,  Adrien
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Arrigucci,  Marco
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Carminati,  Marco
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Deda,  Griseld
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Fiorini,  Carlo
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Geigenberger,  Katrin
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Glas,  Cynthia
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Greiner,  Jochen
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Hindenberger,  Peter
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

King,  Pietro
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Lechner,  Peter
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Losekamm,  Martin
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Mertens,  Susanne
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Meßmann,  David
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Rückerl,  Sebastian
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Toscano,  Lorenzo
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Walter,  Ulrich
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

Willers,  Michael
Max Planck Institute for Physics, Max Planck Society and Cooperation Partners;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Cojocari, I., Meier, M., Laurent, P., Laviron, A., Arrigucci, M., Carminati, M., et al. (2023). Calorimeter calibration of the ComPol CubeSat gamma-ray polarimeter. Nuclear Instruments and Methods in Physics Research Section A, 1046, 167662. doi:10.1016/j.nima.2022.167662.


Cite as: https://hdl.handle.net/21.11116/0000-000F-1286-5
Abstract
ComPol is a proposed CubeSat mission dedicated to long-term study of gamma-ray polarisation of astrophysical objects. Besides spectral and timing measurements, polarisation analysis can be a powerful tool in constraining current models of the geometry, magnetic field structure and acceleration mechanisms of different astrophysical sources. The ComPol payload is a Compton telescope optimised for polarimetry and consists of a 2 layer stacked detector configuration. The top layer, the scatterer, is a Silicon Drift Detector matrix developed by the Max Planck Institute for Physics and Politecnico di Milano. The second layer is a calorimeter consisting of a CeBr scintillator read-out by silicon photo-multipliers developed at CEA Saclay. This paper presents the results of the prototype calorimeter calibration campaign, executed in March 2022 at IJCLab Orsay and simulations of the expected performance of the polarimeter using updated performance figures of the detectors.