Saturated patterned excitation microscopy - a concept for optical resolution improvement

MPS-Authors
/persons/resource/persons15206

Heintzmann,  R.
Department of Molecular Biology, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons15286

Jovin,  T. M.
Department of Molecular Biology, MPI for biophysical chemistry, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)

599549.pdf
(Publisher version), 662KB

Supplementary Material (public)
There is no public supplementary material available
Citation

Heintzmann, R., Jovin, T. M., & Cremer, C. (2002). Saturated patterned excitation microscopy - a concept for optical resolution improvement. Journal of the Optical Society of America A-Optics Image Science and Vision, 19(8), 1599-1609. Retrieved from http://www.opticsinfobase.org/viewmedia.cfm?uri=josaa-19-8-1599&seq=0.


Cite as: https://hdl.handle.net/11858/00-001M-0000-0012-F34C-6
Abstract
The resolution of optical microscopy is limited by the numerical aperture and the wavelength of light. Many strategies for improving resolution such as 4Pi and (IM)-M-5 have focused on an increase of the numerical aperture, Other approaches have based resolution improvement in fluorescence microscopy on the establishment of a nonlinear relationship between local excitation light intensity in the sample and in the emitted light. However, despite their innovative character, current techniques such as stimulated emission depletion (STED) and ground-state depletion (GSD) microscopy require complex optical configurations and instrumentation to narrow the point-spread function. We develop the theory of nonlinear patterned excitation microscopy for achieving a substantial improvement in resolution by deliberate saturation of the fluorophore excited state. The postacquisition manipulation of the acquired data is computationally more complex than in STED or GSD, but the experimental requirements are simple. Simulations comparing saturated patterned excitation microscopy with linear patterned excitation microscopy (also referred to in the literature as structured illumination or harmonic excitation light microscopy) and ordinary widefield microscopy are presented and discussed. The effects of photon noise are included in the simulations. (C) 2002 Optical Society of America.