English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Pulse shape discrimination studies with a Broad-Energy Germanium detector for signal identification and background suppression in the GERDA double beta decay experiment

MPS-Authors
/persons/resource/persons30348

Budjáš,  Dusan
Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society;

/persons/resource/persons30273

Barnabé-Heider,  Marik
Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society;

/persons/resource/persons30376

Chkvorets,  Oleg
Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society;

/persons/resource/persons31005

Schönert,  Stefan
Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Budjáš, D., Barnabé-Heider, M., Chkvorets, O., Khanbekov, N., & Schönert, S. (2009). Pulse shape discrimination studies with a Broad-Energy Germanium detector for signal identification and background suppression in the GERDA double beta decay experiment. Journal of Instrumentation, 4(October 2009): 10007, pp. 1-23. doi:10.1088/1748-0221/4/10/P10007.


Cite as: https://hdl.handle.net/11858/00-001M-0000-0011-740F-0
Abstract
First studies of event discrimination with a Broad-Energy Germanium (BEGe) detector are presented. A novel pulse shape method, exploiting the characteristic electrical field distribution inside BEGe detectors, allows to identify efficiently single-site events and to reject multi-site events. The first are typical for neutrinoless double beta decays (0νββ) and the latter for backgrounds from gamma-ray interactions. The obtained survival probabilities of back­grounds at energies close to Qββ(76Ge) = 2039 keV are (0.93 ± 0.08)% for events from 60Co, (21 ± 3)% from 226Ra and (40 ± 2)% from 228Th. This background suppression is achieved with (89 ± 1)% acceptance of 228Th double escape events, which are dominated by single site inter­actions. Approximately equal acceptance is expected for 0νββ-decay events. Collimated beam and Compton coincidence measurements demonstrate that the discrimination is largely inde­pendent of the interaction location inside the crystal and validate the pulse-shape cut in the energy range of Qββ. The application of BEGe detectors in the GERDA and the Majorana double beta decay experiments is under study.