English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Shack-Hartmann wave front measurements in cortical tissue for deconvolution of large three-dimensional mosaic transmitted light brightfield micrographs

MPS-Authors
/persons/resource/persons84910

Oberlaender,  M
Emeritus Group: Cortical Column in silico / Sakmann, MPI of Neurobiology, Max Planck Society;

/persons/resource/persons39046

Sakmann,  B.
Emeritus Group: Cortical Column in silico / Sakmann, MPI of Neurobiology, Max Planck Society;

Hippler,  S.
Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)

j.1365-2818.2009.03118.x.pdf
(Publisher version), 2MB

Supplementary Material (public)
There is no public supplementary material available
Citation

Oberlaender, M., Broser, P. J., Sakmann, B., & Hippler, S. (2009). Shack-Hartmann wave front measurements in cortical tissue for deconvolution of large three-dimensional mosaic transmitted light brightfield micrographs. Journal of Microscopy (Oxford), 233(2), 275-289. doi:10.1111/j.1365-2818.2009.03118.x.


Cite as: https://hdl.handle.net/11858/00-001M-0000-0012-20B3-A
Abstract
We present a novel approach for deconvolution of 3D image stacks of cortical tissue taken by mosaic/optical-sectioning technology, using a transmitted light brightfield microscope. Mosaic/optical-sectioning offers the possibility of imaging large volumes (e.g. from cortical sections) on a millimetre scale at sub-micrometre resolution. However, a blurred contribution from out-of-focus light results in an image quality that usually prohibits 3D quantitative analysis. Such quantitative analysis is only possible after deblurring by deconvolution. The resulting image quality is strongly dependent on how accurate the point spread function used for deconvolution resembles the properties of the imaging system. Since direct measurement of the true point spread function is laborious and modelled point spread functions usually deviate from measured ones, we present a method of optimizing the microscope until it meets almost ideal imaging conditions. These conditions are validated by measuring the aberration function of the microscope and tissue using a Shack-Hartmann sensor. The analysis shows that cortical tissue from rat brains embedded in Mowiol and imaged by an oil-immersion objective can be regarded as having a homogeneous index of refraction. In addition, the amount of spherical aberration that is caused by the optics or the specimen is relatively low. Consequently the image formation is simplified to refraction between the embedding and immersion medium and to 3D diffraction at the finite entrance pupil of the objective. The resulting model point spread function is applied to the image stacks by linear or iterative deconvolution algorithms. For the presented dataset of large 3D images the linear approach proves to be superior. The linear deconvolution yields a significant improvement in signal-to-noise ratio and resolution. This novel approach allows a quantitative analysis of the cortical image stacks such as the reconstruction of biocytin-stained neuronal dendrites and axons.