English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Hardware injection of simulated continuous gravitational wave signals for GEO 600

MPS-Authors

Weiland,  Uta
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons40460

Heinzel,  Gerhard
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

Woan,  G.
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

Ward,  G.
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)

119887.pdf
(Publisher version), 118KB

Supplementary Material (public)
There is no public supplementary material available
Citation

Weiland, U., Heinzel, G., Woan, G., & Ward, G. (2004). Hardware injection of simulated continuous gravitational wave signals for GEO 600. Classical and Quantum Gravity, 21, S861-S865.


Cite as: https://hdl.handle.net/11858/00-001M-0000-0013-513A-8
Abstract
Search algorithms for continuous gravitational waves are best tested by injecting simulated signals into the detector hardware. These signals need high phase and amplitude stability for reliable calibration. At GEO 600 we have developed an instrument to inject a simulated pulsar signal with a phase error less than 1% of 2 from the correct signal phase. The injection can run over several months and can recover from interruptions. A key component of the instrument is an analogue electronic signal that can be applied to an actuator of one of the test masses of the interferometer. For the generation of this signal a microcontroller is operated as a direct digital frequency synthesiser (DDS). A digital phase locked loop (PLL) on a control computer controls the phase accumulator of the microcontroller via its phase increment register. The signal to be injected is calculated within the LIGO/LSC algorithm library on the control computer.