Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Maintaining high precision of isotope ratio analysis over extended periods of time

Brand, W. A. (2009). Maintaining high precision of isotope ratio analysis over extended periods of time. Isotopes in Environmental and Health Studies, 45(2), 135-149. doi:10.1080/10256010902869097.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
BGC1289.pdf (Verlagsversion), 672KB
 
Datei-Permalink:
-
Name:
BGC1289.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute for Biogeochemistry, MJBK; )
MIME-Typ / Prüfsumme:
application/octet-stream
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Brand, Willi A.1, Autor           
Affiliations:
1Service Facility Stable Isotope, Dr. W. A. Brand, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497772              

Inhalt

einblenden:
ausblenden:
Schlagwörter: carbon-13 isotope measurement methods and equipment IAEA measurement strategy nitrogen-15 reference materials reliability of data
 Zusammenfassung: Stable isotope ratios are reliable and long lasting process tracers. In order to compare data from different locations or different sampling times at a high level of precision, a measurement strategy must include reliable traceability to an international stable isotope scale via a reference material (RM). Since these international RMs are available in low quantities only, we have developed our own analysis schemes involving laboratory working RM. In addition, quality assurance RMs are used to control the long-term performance of the delta-value assignments. The analysis schemes allow the construction of quality assurance performance charts over years of operation. In this contribution, the performance of three typical techniques established in IsoLab at the MPI-BGC in Jena is discussed. The techniques are (1) isotope ratio mass spectrometry with an elemental analyser for delta N-15 and delta C-13 analysis of bulk (organic) material, (2) high precision delta C-13 and delta O-18 analysis of CO2 in clean-air samples, and (3) stable isotope analysis of water samples using a high-temperature reaction with carbon. In addition, reference strategies on a laser ablation system for high spatial resolution delta C-13 analysis in tree rings is exemplified briefly.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2009
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1080/10256010902869097
Anderer: BGC1289
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Isotopes in Environmental and Health Studies
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Reading, Berkshire [u.a.] : Gordon and Breach Publishers
Seiten: - Band / Heft: 45 (2) Artikelnummer: - Start- / Endseite: 135 - 149 Identifikator: ISSN: 1025-6016
CoNE: https://pure.mpg.de/cone/journals/resource/954926944750