日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細


公開

学術論文

Image charge shift in high-precision Penning traps

MPS-Authors
/persons/resource/persons59399

Schuh,  M.
Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society;

/persons/resource/persons207033

Heiße,  F.
Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society;

/persons/resource/persons30667

Ketter,  J.
Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society;

/persons/resource/persons128164

Köhler-Langes,  F.
Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society;

/persons/resource/persons207035

Rau,  S.
Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society;

/persons/resource/persons137084

Segal,  T.
Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society;

/persons/resource/persons31090

Sturm,  S.
Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society;

/persons/resource/persons30312

Blaum,  K.
Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society;

External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
フルテキスト (公開)
公開されているフルテキストはありません
付随資料 (公開)
There is no public supplementary material available
引用

Schuh, M., Heiße, F., Eronen, T., Ketter, J., Köhler-Langes, F., Rau, S., Segal, T., Quint, W., Sturm, S., & Blaum, K. (2019). Image charge shift in high-precision Penning traps. Physical Review A, 100(2):. doi:10.1103/PhysRevA.100.023411.


引用: https://hdl.handle.net/21.11116/0000-0004-EC85-C
要旨
An ion in a Penning trap induces image charges on the surfaces of the trap electrodes. These induced image charges are used to detect the ion's motional frequencies, but they also create an additional electric field, which shifts the free-space cyclotron frequency typically at a relative level of several 10−11. In various high-precision Penning-trap experiments, systematics and their uncertainties are dominated by this so-called image charge shift (ICS). The ICS is investigated in this work by a finite-element simulation and by a dedicated measurement technique. Theoretical and experimental results are in excellent agreement. The measurement is using singly stored ions alternately measured in the same Penning trap. For the determination of the ion's magnetron frequency with relative precision of better than 10 parts per billion, a Ramsey-like technique has been developed. In addition, numerical calculations are carried out for other Penning traps and agree with older ICS measurements.