日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  One‐minute whole‐brain magnetization transfer ratio imaging with intrinsic B1‐correction

Afshari, R., Santini, F., Heule, R., Meyer, C., & Pfeuffer, J. (2021). One‐minute whole‐brain magnetization transfer ratio imaging with intrinsic B1‐correction. Magnetic Resonance in Medicine, 85(5), 2686-2695. doi:10.1002/mrm.28618.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0007-9DB1-0 版のパーマリンク: https://hdl.handle.net/21.11116/0000-000F-4208-E
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
説明:
-
OA-Status:
Not specified

作成者

表示:
非表示:
 作成者:
Afshari, R, 著者
Santini, F, 著者
Heule, R1, 著者           
Meyer, CH, 著者
Pfeuffer, J, 著者           
所属:
1Institutional Guests, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_3505519              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose: Magnetization transfer ratio (MTR) histograms are used widely for the assessment of diffuse pathological changes in the brain. For broad clinical application, MTR scans should not only be fast, but confounding factors should also be minimized for high reproducibility. To this end, a 1-minute whole-brain spiral MTR method with intrinsic B1-field correction is introduced.

Methods: A spiral multislice spoiled gradient-echo sequence with adaptable magnetization-transfer saturation pulses (angle β) is proposed. After a low-resolution single-shot spiral readout and a dummy preparation period, high-resolution images are acquired using an interleaved spiral readout. For whole-brain MTR imaging, 50 interleaved slices with three different magnetization-transfer contrasts (β = 0°, 350°, and 550°) together with an intrinsic B1-field map are recorded in 58.5 seconds on a clinical 3T system. From the three contrasts, two sets of MTR images are derived and used for subsequent B1 correction, assuming a linear dependency on β. For validation, a binary spin bath model is used.

Results: For the proposed B1-correction scheme, numerical simulations indicate for brain tissue a decrease of about a factor of 10 for the B1-related bias on MTR. As a result, following B1 correction, MTR differences in gray and white matter become markedly accentuated, and the reproducibility of MTR histograms from scan-rescan experiments is improved. Furthermore, B1-corrected MTR histograms show a lower variability for age-matched normal-appearing brain tissue.

Conclusion: From its speed and offering intrinsic B1 correction, the proposed method shows excellent prospects for clinical studies that explore magnetization-transfer effects based on MTR histogram analysis.

資料詳細

表示:
非表示:
言語:
 日付: 2020-122021-05
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/mrm.28618
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: New York : Wiley-Liss
ページ: - 巻号: 85 (5) 通巻号: - 開始・終了ページ: 2686 - 2695 識別子(ISBN, ISSN, DOIなど): ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149