Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Hochschulschrift

Determination of the Krypton-Impurity Evolution in the XENON1T Detector and Optimization of Separation Columns for Krypton in Xenon Assays

MPG-Autoren
/persons/resource/persons216612

Winkler,  Daniel
Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society;

Externe Ressourcen
Es sind keine externen Ressourcen hinterlegt
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)

MA_Winkler.pdf
(beliebiger Volltext), 12MB

Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Winkler, D. (2020). Determination of the Krypton-Impurity Evolution in the XENON1T Detector and Optimization of Separation Columns for Krypton in Xenon Assays. Master Thesis, Ruprecht-Karls-Universität, Heidelberg.


Zitierlink: https://hdl.handle.net/21.11116/0000-0007-CFA8-3
Zusammenfassung
The XENON experiment aims for the direct detection of dark matter with liquid xenon
as target material for so-called WIMPs (Weakly Interacting Massive Particles), which
represent one of the main candidates for particle dark matter. As the expected signal
rate is less than a couple of events per year, it is mandatory to understand and reduce
possible background contributions. The radioactive krypton isotope 85Kr is among the
most serious internal background contributions, which can mimic a WIMP signal. However,
krypton traces are successfully removed from liquid xenon by cryogenic distillation. The
external monitoring of the remaining krypton traces using a rare gas mass spectrometer
(RGMS) sets the framework of this work. First, the krypton concentration evolution of the
XENON1T detector was determined. A change in the signal shape of RGMS required a new
analysis procedure, including a thorough and much improved error treatment. Within this
analysis, the lowest krypton in xenon concentration ever measured in a running detector
is set. Second, different adsorbents were examined and characterized to optimize the
separation of krypton from xenon, necessary for the present analysis of concentrations in
the ppq regime. Due to the posed requirements, such as resolution, peak width, and tailing,
the activated carbon ShinCarbon turned out to be the best candidate. The ShinCarbon
column will be an integral part of a planned system called AUTO-RGMS and will lead to a
significantly improved separation efficiency, a better reproducibility, and a lower detection
limit.