Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Poster

Investigations on accelerated imaging at 9.4T with electronically modulated time-varying receive sensitivities

MPG-Autoren
/persons/resource/persons230667

Glang,  F
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons133443

Buckenmaier,  K
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons192600

Bause,  J
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84372

Loktyushin,  A
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons133464

Avdievitch,  N
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84187

Scheffler,  K
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Glang, F., Buckenmaier, K., Bause, J., Loktyushin, A., Avdievitch, N., & Scheffler, K. (2021). Investigations on accelerated imaging at 9.4T with electronically modulated time-varying receive sensitivities. Poster presented at 2021 ISMRM & SMRT Annual Meeting & Exhibition (ISMRM 2021).


Zitierlink: https://hdl.handle.net/21.11116/0000-0008-8656-0
Zusammenfassung
In this work, it is assessed how electronically modulated time-varying receive sensitivities can improve parallel imaging reconstruction at 9.4T. The required sensitivity modulation is achieved by introducing variable capacitance diodes (varactors) in the receive loops that can be independently adjusted to modify B1- profiles. A prototype 4 channel receive array was built, and measured and simulated receive profiles were compared. Additionally, simulations were conducted regarding potential for g-factor improvement. It was found that potential improvements strongly depend on the B1- switching patterns during k-space acquisition, where strongest improvements are to be expected from fast B1- modulations.